Automatic restart (retry) related parameters.
Func.
Name
Code
Restart mode on power
failure / under-voltage trip
Allowable under-voltage
power failure time
Retry wait time before motor
restart
Instantaneous power failure
/ under-voltage trip alarm
enable
Number of restarts on power
failure / under-voltage trip
events
Restart frequency threshold
Restart mode on over voltage
/ over current trip
"b" Function
Description
Select inverter restart method,
Five option codes:
Alarm output after trip, no
automatic restart
Restart at 0Hz
Resume
frequency matching
Resume previous freq.
after freq. matching, then
decelerate to stop and
display trip info
Resume operation after
active freq. matching
The amount of time a power
input under-voltage can occur
without tripping the power
failure alarm. Range is 0.3 to
25 sec. If under-voltage exists
longer than this time, the
inverter trips, even if the
restart mode is selected.
Time delay after under-voltage
condition goes away, before the
inverter runs motor again.
Range is 0.3 to 100 seconds.
Three option codes:
Disable
Enable
Disable during stop and
decelerates to a stop
Two option codes:
Restart 16 times
Always restart
Restart the motor from 0Hz if
the frequency becomes less
than this set value during the
motor is coasting, range is 0 to
400Hz
Select inverter restart method,
Five option codes:
Alarm output after trip, no
automatic restart
Restart at 0Hz
Resume operation after
frequency matching
Resume previous freq.
after active freq. matching,
then decelerate to stop and
display trip info
Resume operation after
active freq. matching
Run
Mode
Edit
operation
after
345
Defaults
Initial data
Units
00
1.0
sec.
1.0
sec.
00
00
0.00
Hz
00