The external register number you would like to use is already listed in Hitachi register number(in
5 5 5 5
this case, overlapping with high order of 32-bit parameter)
* * * * Below setting must be entered from the operator before Modbus communication, with power cycle.
External register
number
1218h
( A 021 ( H IGH ) )
When
[O] input active range start voltage
(1) Reading Holding Register [03h] 、 t arget register : E xternal Register
Query:
No
1
Slave address
2
Function code
3
Register start address (high order)
4
Register start address (low order)
5
Number of holding registers
(high order)
6
Number of holding registers (low order)
7
CRC-16 (high order)
8
CRC-16 (low order)
Response:
No
Field Name
1
Slave address
2
Function code
3
Data size (in bytes)
4
Register data 1 (high order)
5
Register data 1 (low order)
6
CRC-16 (high order)
7
CRC-16 (low order)
Internal register
number
120Fh
( A 013 )
= 33 %( 21h)
Field Name
Example
(Hex)
5C
Scaling
1.000
Example
(Hex)
01
03
12
17
00
01
31
76
01
03
02
00
21
78
Ver.3− − − − 41