Standard Functions
NOTE:. Mark "" in A line of [ Run Mode Edit] shows the accessible parameters when b031 is not set "10",
high level access.
NOTE:. Mark "" in B line of [ Run Mode Edit] shows the accessible parameters when b031 is set "10",
high level access
Func.
Name
Code
Frequency source
Frequency source,
2
motor
nd
Run command source
Run command source,
2
motor
nd
Base frequency
Base frequency,
2
motor
nd
Maximum frequency
Maximum frequency,
2
motor
nd
[AT] selection
[O] input active range start
frequency
[O] input active range end
frequency
[O] input active range start
voltage
[O] input active range end
voltage
[O] input start frequency
enable
"A" Function
Description
Eight options; select codes:
POT on ext. operator
Control terminal
Function F001 setting
Modbus network input
Option
Pulse train input
via EzSQ
Calculate function output
Four options; select codes:
Control terminal
Run key on keypad,
or digital operator
Modbus network input
Option
Settable from 30 Hz to the maximum
frequency()
Settable from 30 Hz to the 2
frequency()
Settable from the base
frequency to 400 Hz
Settable from the 2
nd
frequency to 400 Hz
Three options; select codes:
...Select between [O] and [OI] at [AT]
(ON=OI, OFF=O)
...Select between [O] and external POT
at [AT]
(ON=POT, OFF=O)
...Select between [OI] and external
POT at [AT]
(ON=POT, OFF=OI)
The output frequency corresponding to
the analog input range starting point,
range is 0.00 to 400.0
The output frequency corresponding to
the analog input range ending point,
range is 0.0 to 400.0
The starting point (offset) for the active
analog input range,
range is 0. to 100.
The ending point (offset) for the active
analog input range,
range is 0. to 100.
Two options; select codes:
Use offset ( value)
Use 0Hz
Run
Mode
Edit
A
nd
maximum
base
Ver.249
Defaults
B
Initial data
Units
01
01
01
01
50.0
Hz
50.0
Hz
50.0
Hz
50.0
Hz
00
0.00
Hz
0.00
Hz
0.
%
100.
%
01