Hitachi WJ200-001S Instruction Manual page 603

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Ver.3− − − − 94
(iv) List of registers
Register
Function name
No.
1103h
Acceleration time (1)
1104h
1105h
Deceleration time (1)
1106h
1107h
Keypad Run key routing
1108h to
Unused
1200h
: Range modified from version 3.0
*1
(v) List of registers (function modes)
Parameter group A
Register
Function name
No.
1201h
Frequency source
1202h
Run command source (*)
1203h
Base frequency
1204h
Maximum frequency
1205h
[AT] selection
1206h to
(Reserved)
120Ah
120Bh
[O] input active range start
frequency
120Ch
120Dh
[O] input active range end
frequency
120Eh
[O] input active range start
120Fh
voltage
[O] input active range end
1210h
voltage
[O] input start frequency
1211h
select
1212h
Analog input filter.
1213h
EzSQ selection
1214h
(Reserved)
Multi speed operation
1215h
selection
1216h
Multi-speed freq. 0
1217h
1218h
Multi-speed freq. 1
1219h
121Ah
Multi-speed freq. 2
121Bh
121Ch
Multi-speed freq. 3
121Dh
121Eh
Multi-speed freq. 4
121Fh
1220h
Multi-speed freq. 5
1221h
1222h
Multi-speed freq. 6
1223h
1224h
Multi-speed freq. 7
1225h
After changing the setting, keep the time 40ms or longer before actually give run command
Function code
R/W
F002 (high)
*1
R/W
F002 (low)
F003 (high)
*1
R/W
F003 (low)
F004
R/W
-
-
Function code
R/W
A001
R/W
A002
R/W
A003
R/W
A004
R/W
A005
R/W
-
-
A011 (high)
R/W
A011 (low)
A012 (high)
R/W
A012 (low)
A013
R/W
A014
R/W
A015
R/W
A016
R/W
A017
R/W
-
-
A019
R/W
A020 (high)
R/W
A020 (low)
R/W
A021 (high)
R/W
A021 (low)
R/W
A022 (high)
R/W
A022 (low)
R/W
A023 (high)
R/W
A023 (low)
R/W
A024 (high)
R/W
A024 (low)
R/W
A025 (high)
R/W
A025 (low)
R/W
A026 (high)
R/W
A026 (low)
R/W
A027 (high)
R/W
A027 (low)
R/W
Monitoring and setting items
0 to 360000
0 to 360000
0 (forward rotation), 1 (reverse rotation)
Inaccessible
Monitoring and setting items
0 (keypad potentiometer), 1 (control circuit terminal
block), 2 (digital operator), 3 (Modbus), 4 (option ), 6
(pulse train input), 7 (easy sequence), 10 (operation
function result)
1 (control circuit terminal block), 2 (digital operator),
3 (Modbus), 4 (option)
300 to "maximum frequency"
300 to 4000(10000)
0 (switching between O and OI terminals),
2 (switching between O terminal and keypad
potentiometer),
3 (switching between OI terminal and keypad
potentiometer)
-
0 to 40000(100000)
0 to 40000(100000)
0 to "[O]-[L] input active range end voltage"
"[O]-[L] input active range start voltage" to 100
0 (external start frequency), 1 (0 Hz)
1 to 30 or 31 (500 ms filter ±0.1 Hz with hysteresis)
0 (disabling), 1 (PRG terminal) , 2 (Always)
-
0 (binary), 1 (bit)
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
Data resolution
0.01 [s]
0.01 [s]
-
-
Data resolution
-
-
0.1 [Hz]
0.1 [Hz]
-
-
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]
-
1
-
-
-
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]