Receiver setup: Power management

Background Information
Configure the power up and low power behaviour of the receiver according to the intended use case.
Setting Descriptions
The table below describes the settings that can be configured on the Power management page.
Power supply
Primary supply
Internal battery
Charging mode
Description
Select the primary power supply.
External 1
External 1 is used as the primary supply.
External 2
External 2 is used as the primary supply.
Power over Ethernet (PoE)
PoE is used as the primary supply (requires network connection with Power
over Ethernet compliant with the standard IEEE 802.3, class 0 PoE solution).
If the selected primary power supply is no longer available then
the receiver automatically switches to a secondary power supply,
if available. The receiver automatically selects the power supply
in the following order of priority
1. External 1 or 2 (whichever is available)
2. Power over Ethernet (PoE)
3. Internal battery
PoE supplies 13 Watts of current. This is insufficient for some
external devices. If insufficient current is available for external
devices, they will be disabled by the receiver. Please check the
devices power specification before use or use an external power
supply to power the device.
Description
Select the internal battery charging mode.
UPS mode