Logging Session Wizard: Session Timing - Leica GR10 Operational Manual

Hide thumbs Also See for GR10:
Table of Contents

Advertisement

Operational Manual (Online Help)

Logging session wizard: Session timing

Background information
Timed logging sessions consider the configured file length and the configured interval length.
Example: If a timed logging session is configured to
Start logging at a certain date at 15:00h
End logging after 30min
No of repeats: repeat 10 times
Start next session: 10min after last session ended
And the file length is set to 1h, the behaviour will be as follows:
1. The receiver starts logging at 15:00h because the first interval starts.
2. The receiver stops logging and closes the file at 15:30h because the first interval ends.
3. The receiver starts logging into a new file at 15:40h because the second interval starts.
4. The receiver closes this file at 15:59:59h and immediately starts a new file because of the 1h file rollover.
5. The receiver stops logging and closes this file at 16:10h because the second interval ends.
Setting Descriptions
The table below describes the settings that can be configured on the Session timing page.
Please note that the time settings will refer to the receivers defined Time zone. To set the receivers Time zone, go to GNSS
management / Site name and coordinates.
Setting
Start logging at
End logging
No. of intervals
Start next session
190
Description
Configure the start time and date of the logging session.
Use the date and time pickers to select the logging start time.
Configure the end time and date or the duration of the logging session.
End logging
at: Select a time and date for the first logging interval to end.
after: Select a time interval after which the first logging interval ends.
no end: The logging session starts at the defined date and time, and
runs continuously.
The minimum time interval for a logging session to run is 5 minutes.
Configure the number of repeats for the current logging session.
This setting is only available if End logging is set to at or after.
Select
Select run to enter a number of repetitions for this logging session.
Select repeat infinitely to configure a logging session with no defined
end.
Select run once to configure only one interval for a logging session.
This setting is only active if repeat infinitely or run is selected in the No. of
repeats.