Info-Center Switch-On - Huawei Quidway S3900 series Command Manual

Hide thumbs Also See for Quidway S3900 series:
Table of Contents

Advertisement

Command Manual – Information Center
Quidway S3900 Series Ethernet Switches-Release 1510
Note:
By enabling the synchronous terminal output function with the info-center
synchronous command, you can avoid users' input from being interrupted by
system information output.
Running the info-center synchronous command during debugging information
collection may result in a command prompt echoed after each item of debugging
information. To avoid unnecessary output, it is recommended that you disable
synchronous terminal output in such cases.
Example
# Enable synchronous terminal output.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway]info-center synchronous
Current IC terminal output sync is on

1.1.16 info-center switch-on

Syntax
info-center switch-on { unit unit-id | master | all } [ debugging | logging | trapping ]*
undo info-center switch-on { unit unit-id | master | all } [ debugging | logging |
trapping ]*
View
System view
Parameter
unit unit-id: Specifies a switch on which information output function is to be
enabled/disabled.
master: Controls the switch that serves as master.
all: Controls all switches within the fabric.
debugging: Enables the debugging information output source.
logging: Enables the log information output source.
trapping: Enables the trap information output source.
Description
Use the info-center switch-on command to enable information output function for a
specified switch in a fabric.
Huawei Technologies Proprietary
1-18
Chapter 1 Information Center Configuration