Command Manual - HWPing
Quidway S3900 Series Ethernet Switches-Release 1510
Parameter
interval: Automatic test interval. It ranges from 0 to 65535 seconds and defaults to 0
meaning no automatic test.
Description
Use the frequency command to configure an automatic test interval.
Use the undo frequency command to disable automatic test.
The system automatically tests at intervals specified by this command, where the
argument interval is greater than 0.
Related command: count.
Example
# Set the automatic test interval of the "administrator-icmp" test group to 10 seconds.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] hwping administrator icmp
[Quidway-hwping-administrator-icmp] frequency 10

1.1.5 hwping

Syntax
hwping administrator-name operation-tag
undo hwping administrator-name operation-tag
View
System view
Parameter
administrator-name: Name of the administrator creating an HWPing test group, a
string of 1 to 32 characters.
operation-tag: Test operation tag, a string of 1 to 32 characters long.
Description
Use the hwping command to create an HWPing test group and enter HWPing test
group view..
Use the undo hwping command to delete the HWPing test group.
Example
# Create an HWPing test group, where the administrator name is "administrator" and
the test operation tag is "icmp".
Huawei Technologies Proprietary