Command Manual – System Maintenance and Debugging
Quidway S3900 Series Ethernet Switches-Release 1510
Related command: clock datetime.
Example
# Display the current date and time of the system.
<Quidway> display clock
18:36:31 beijing Sat 2002/02/02
Time Zone : beijing add 01:00:00
Summer-Time : bj one-off 01:00:00 2003/01/01 01:00:00 2003/08/08 01:00:00
Table 1-1 Description on the fields of the display clock command
18:36:31 beijing Sat 2002/02/02
Time Zone
Summer-Time

1.2.2 display debugging

Syntax
display debugging [ fabric | unit unit-id ] [ interface interface-type interface-number ]
[ module-name ]
View
Any view
Parameter
fabric: Displays the enabled debugging of the switches in the Fabric.
unit-id: Unit ID of a switch.
interface-type: Interface type.
interface-number: Interface number.
module-name: Functional module name.
Description
Use the display debugging command to display enabled debugging on a specified
device. Executing this command without any parameter will display all enabled
debugging.
Related command: debugging.
Example
# Display enabled debugging on unit 1.