Delta ASDA-B2 Series User Manual page 161

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 6 Control Modes of Operation
The wiring diagram of using mechanical brake:
NOTE
Timing diagram of control power and main power:
L1, L2
Control Circuit
Power
5V
Control Circuit
Power
R, S, T
Main Circuit
Power
BUS Voltage
READY
SERVO
READY
SERVO ON
(DI Input)
SERVO ON
(DO Output)
Position \ Speed \
Torque Command
Input
6-50
(1) Please refer to Chapter 3, Wiring.
(2) The brake signal controls the solenoid valve, provides power to
the brake and enables the brake.
(3) Please note that there is no polarity in coil brake.
(4) Do not use brake power and control power (VDD) at the same
time.
1 sec
> 0msec
800ms
2 sec
1 msec (min)+
Input available
Response Filter Time of Digital Input (
ASDA-B2
P2-09)
Revision May, 2018