ASDA-B2
P0-05■
Reserved
P0-06■
Reserved
P0-07■
Reserved
P0-08★
TSON Servo Startup Time
Operation
Interface:
Default: 0
Control
Mode:
Range: High Word: 0 ~ 65535
Data Size: 16-bit
Format: Decimal
Settings: High Word: Servo enable time
P0-09★
CM1
Operation
Interface:
Default: -
Control
Mode:
Range: -
Data Size: 32-bit
Format: Decimal
Settings: The setting value which is set by P0-17 should be monitored via
Revision May, 2018
Panel/Software
-
Unit: Hour
Low Word: 0 ~ 65535
Low Word: Servo power on time
Status Monitor Register 1
Panel/Software
ALL
Unit: -
P0-09.
For example, if P0-17 is set to 3, when accessing P0-09, it obtains
the total feedback pulse number of motor encoder. For MODBUS
communication, two 16bit data, 0012H and 0013H will be read as
a 32bit data; (0013H : 0012H) = (Hi-word : Low-word). Set P0-02 to
23, the panel displays "VAR-1" first, and then shows the content of
P0-09.
Communication
Communication
Chapter 7 Parameters
Address: 000AH
000BH
Address: 000CH
000DH
Address: 000EH
000FH
Address: 0010H
0011H
Related Section: N/A
Address: 0012H
0013H
Related Section: