Delta ASDA-B2 Series User Manual page 242

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

ASDA-B2
P3-02
PTL
Operation
Interface:
Default: 0x0066
Control
Mode:
Range: 0x0000 ~ 0x0088
Data Size: 16-bit
Format: Hexadecimal
Settings: The definition of the setting value is as the followings:
Revision May, 2018
Settings:
0: 4800
1: 9600
2: 19200
3: 38400
4: 57600
5: 115200
Communication Protocol
Panel / Software
ALL
Unit: N/A
COM Port
Range
0: 7, N, 2 (MODBUS, ASCII)
1: 7, E, 1 (MODBUS, ASCII)
2: 7, O,1 (MODBUS, ASCII)
3: 8, N, 2 (MODBUS, ASCII)
4: 8, E, 1 (MODBUS, ASCII)
5: 8, O, 1 (MODBUS, ASCII)
6: 8, N, 2 (MODBUS, RTU)
7: 8, E, 1 (MODBUS, RTU)
8: 8, O, 1 (MODBUS, RTU)
Communication
0
Z
-
-
RS-485
0
0
Chapter 7 Parameters
Address: 0304H
0305H
Related Section:
8.2
Y
X
RS-232
0 ~ 8
0 ~ 8
7-81

Hide quick links: