P2-43
NCF2 Resonance Suppression (Notch Filter) 2
Operation
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Settings: The second setting value of resonance frequency. If P2-44 is set
P2-44
DPH2
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings: The second resonance suppression (notch filter) attenuation
Revision May, 2018
Panel/Software
ALL
Unit: Hz
Decimal
to 0, this function is disabled. P2-23 and P2-24 are the first Notch
filter.
Resonance Suppression (Notch Filter)
Attenuation Rate (2)
Panel/Software
ALL
Unit: dB (0: Disable the function of notch filter)
Decimal
rate. When this parameter is set to 0, the function of Notch filter
is disabled.
Chapter 6 Control Modes of Operation
Communication
Communication
Address: 0256H
0257H
Related Section:
Section 6.3.7
Address: 0258H
0259H
Related Section:
Section 6.3.7