Delta ASDA-B2 Series User Manual page 141

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 6 Control Modes of Operation
P2-45
NCF3 Resonance Suppression (Notch Filter) 3
Operation
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Settings: The third group of mechanism resonance frequency setting value.
P2-46
DPH3
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings: The third group of resonance suppression (Notch filter)
6-30
Panel/Software
ALL
Unit: Hz
Decimal
If P2-46 is set to 0, this function will be disabled. P2-23 and
P2-24 are the first group of resonance suppression (Notch filter).
Resonance Suppression (Notch Filter)
Attenuation Rate (3)
Panel/Software
ALL
Unit: dB
Decimal
attenuation rate. Set the value to 0 to disable the function of
Notch filter.
Communication
Communication
ASDA-B2
Address: 025AH
025BH
Related Section:
Section 6.3.7
Address: 025CH
025DH
Related Section:
Section 6.3.7
Revision May, 2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents