Delta ASDA-B2 Series User Manual page 194

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

ASDA-B2
P1-20
Reserved
P1-21
Reserved
P1-22
Reserved
P1-23
Reserved
P1-25
VSF1 Low-frequency Vibration Suppression (1)
Operation
Interface:
Default: 1000
Control
Mode:
Range: 10 ~ 1000
Data Size: 16bit
Format: DEC
Example
Settings: The setting value of the first low-frequency vibration suppression.
P1-26
VSG1
Operation
Interface:
Default: 0
Control
Mode:
Range: 0~9 (0: Disable the first low-frequency
Data Size: 16bit
Format: DEC
Settings: The first low-frequency vibration suppression gain. The bigger
Revision May, 2018
Panel/Software
PT
Unit: 0.1Hz
150 = 15 Hz
If P1-26 is set to 0, then it will disable the first low-frequency filter.
Low-frequency Vibration Suppression
Gain (1)
Panel/Software
PT
Unit: -
filter)
value it is, the better the position response will be. However, if the
value is set too big, the motor will not be able to smoothly
operate. It is suggested to set the value to 1.
Communication
Communication
Chapter 7 Parameters
Address: 0128H
0129H
Address: 012AH
012BH
Address: 012CH
012DH
Address: 012EH
012FH
Address: 0132H
0133H
Related Section:
Section 6.2.9
Address: 0134H
0135H
Related Section:
Section 6.2.9
7-33