Delta ASDA-B2 Series User Manual page 304

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

10.1 Specifications of Servo Drives (ASDA-B2 Series)
ASDA-B2 Series
Phase / Voltage
Input Current (3PH)
Unit: Arms
Input Current (1PH)
Unit: Arms
Continuous Output Current
Unit: Arms
Cooling Method
Encoder Resolution /
Feedback Resolution
Main Circuit Control
Control Mode
Regenerative Resistor
Max. Input Pulse Frequency
Pulse Type
Command Source
Smoothing Strategy
E-gear Ratio
Torque Limit
Feed Forward Compensation
Voltage Range
Analog
Command
Resistance
Input
Time Constant
Speed Control Range
Command Source
Smoothing Strategy
Revision May, 2018
Chapter 10 Specifications
100W
200W
01
Three-phase: 170 ~ 255 VAC, 50 / 60 Hz ±5%
Single-phase: 200 ~ 255 VAC, 50 / 60Hz ±5%
0.7
0.9
0.9
Natural cooling
None
Line driver: 500 K (low-speed) / 4 Mpps (high-speed)
Pulse + Symbol, A phase + B phase, CCW pulse + CW pulse
E-gear ratio: N/M time(s). The limit is: (1/50 < N/M < 25600)
Input
*1
400W
750W
02
04
07
1.11
1.86
3.66
1.92
3.22
6.78
1.55
2.6
5.1
17-bit (160000 p/rev)
SVPWM Control
Manual / Auto
Open collector: 200 Kpps
External pulse
Low-pass filter
26
N:1 ~ (2
-1) / M:1 ~(2
Parameter settings
Parameter settings
0 ~ ±10 V
10 KΩ
2.2 us
1:5000
External analog command / Register
Low-pass and S-curve filter
1kW
1.5kW
2kW
10
15
20
Three-phase
170 ~ 255 VAC
50 / 60 Hz ±5%
4.68
5.9
8.76
8.88
10.3
-
7.3
8.3
13.4
Fan cooling
Built-in
31
-1)
DC
3kW
30
9.83
-
19.4
10-1