Delta ASDA-B2 Series User Manual page 32

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

ASDA-B2
Motor Cable Selection and Installation Precautions
The selection of motor cables and installation affect the performance of EMI Filter.
Please follow the precautions mention below.
1. Use the cable that has braid shielding (The effect of double shielding is better)
2. The shield on both sides of the motor cable should be grounded in the shortest
distance and the largest contact area.
3. The protective paint of the U-shape saddle and metal plate should be removed in
order to ensure the good contact. Please see disgram 1.
4. It should have correct connection between the braid shielding of the motor cable and
the metal plate. The braid shielding on both sides of the motor cable should be fixed
by the U-shape saddle and metal plate. Please see diagram 2 for the correct
connection.
Revision May, 2018
Figure 1
Saddle on both ends
Saddle on one end
Figure 2
Chapter 2 Installation
2-11