Delta ASDA-B2 Series User Manual page 195

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 7 Parameters
P1-27
VSF2 Low-frequency Vibration Suppression (2)
Operation
Interface:
Default: 1000
Control
Mode:
Range: 10 ~ 1000
Data Size: 16bit
Format: DEC
Example 150 = 15 Hz
Settings: The setting value of the second low-frequency vibration
P1-28
VSG2
Operation
Interface:
Default: 0
Control
Mode:
Range: 0~9 (0: Disable the second low-frequency
Data Size: 16bit
Format: DEC
Settings: The second low-frequency vibration suppression gain. The bigger
P1-31
Reserved
7-34
Panel/Software
PT
Unit: 0.1Hz
suppression. If P1-28 is set to 0, then it will disable the second
low-frequency filter.
Low-frequency Vibration Suppression
Gain (2)
Panel/Software
PT
Unit: -
filter)
value it is, the better the position response will be. However, if the
value is set too big, the motor will not be able to smoothly
operate. It is suggested to set the value to 1.
Communication
Communication
ASDA-B2
Address: 0136H
0137H
Related Section:
Section 6.2.9
Address: 0138H
0139H
Related Section:
Section 6.2.9
Address: 013EH
013FH
Revision May, 2018