The following table lists the display examples of monitor value:
Example of the Displayed
Value
(Dec.)
(Hex.)
(Dec. High)
(Dec. Low)
(Hex. High)
(Hex. Low)
Revision May, 2018
Symbol
Torque input command
Torque input command
Average load
Peak load
Main circuit voltage
Load / Motor Inertia Ratio
(Please note that if the display is 130,
it indicates that the actual inertia is 13.0)
IGBT temperature
Resonance frequency (Low byte is the
first resonance and high byte is the
second one)
The absolute pulse number of encoder
Z phase equals to the homing value, 0.
It will be +5000 or -5000 pulse when
rotating in forward or reverse direction.
16-bit
32-bit
Negative display. If the value is -12345, it displays
1.2.345 (only shows in decimal format; there is no
positive or negative sign for hexadecimal format display).
Description
Status Description
If the value is 1234, it displays 01234 (shows in
decimal format).
If the value is 0x1234, it displays 1234 (shows in
hexadecimal format; the first digit does not show
any).
If the value is 1234567890, the display of the high
byte is 1234.5 and displays 67890 as the low byte
(shows in decimal format).
If the value is 0x12345678, the display of the high
byte is h1234 and displays L5678 as the low byte
(shows in hexadecimal format).
Chapter 4 Panel Display and Operation
[0.1times]
Unit
[Volt]
[%]
[%]
[%]
[Volt]
o
[
C]
[Hz]
-
4-5