Related parameters:
P1-34
TACC Acceleration Constant of S-Curve
Operation
Interface:
Default: 200
Control
Mode:
Range: 1 ~ 20000
Data Size: 16-bit
Display
Format:
Settings: The time that speed command accelerates from 0 to 3000 r/min.
NOTE
.
P1-35
TDEC Deceleration Constant of S-Curve
Operation
Interface:
Default: 200
Control
Mode:
Range: 1 ~ 20000
Data Size: 16-bit
Display
Format:
Settings: The time that speed command decelerates from 3000 r/min to 0.
NOTE
Revision May, 2018
Panel/Software
S
Unit: ms
Decimal
P1-34, P1-35, and P1-36, the acceleration time of speed
command from zero to the rated speed, all can be set
individually.
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
Panel/Software
S
Unit: ms
Decimal
P1-34, P1-35, and P1-36, the deceleration time of speed
command from the rated speed to zero, all can be set
individually.
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
Chapter 6 Control Modes of Operation
Communication
Communication
Address: 0144H
0145H
Related Section:
Section 6.3.3
Address: 0146H
0147H
Related Section:
Section 6.3.3