Chapter 7 Parameters
P2-35
PDEV
Operation
Interface:
Default: 480000
Control
Mode:
Range: 1 ~ 16000000
Data Size: 32-bit
Format: Decimal
Settings: The setting of excessive position control deviation warning in
P2-36
DI9
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 0x015F
Data Size: 16-bit
Format: Hexadecimal
Settings:
7-66
Condition of Excessive Position Control
Deviation Warning
Panel/Software
PT
Unit: pulse
servo drive error display (P0-01).
Extended EDI9 Functional Planning
Panel/Software
ALL
Unit: N/A
(The last two codes are EDI code)
 Input function selection: Please refer to table 7.1
 Input contact: a or b contact
0: Set the input contact as normally closed (b contact)
1: Set the input contact as normally opened (a contact)
Communication
Communication
Input function selection
Input contact
Not in use
ASDA-B2
Address: 0246H
0247H
Related Section: N/A
Address: 0248H
0249H
Related Section: