Chapter 7 Parameters
P3-03
FLT
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1
Data Size: 16-bit
Format: Hexadecimal
Settings: The definition of the setting value is as the following:
P3-04
CWD Communication Time Out
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 20
Data Size: 16-bit
Format: Decimal
Settings: If the setting value is not 0, enable communication timeout
P3-05
CMM Communication Mechanism
Operation
Interface:
Default: 0
Control
Mode:
Range: 0x00 ~ 0x01
Data Size: 16-bit
Format: Hexadecimal
Settings: RS-232 via MOBUS communication or communicate with
7-82
Communication Error Disposal
Panel / Software
ALL
Unit: N/A
0: Warning and keeps running
1: Warning and stops deceleration (The deceleration time is set to
parameter P1-32)
Panel / Software
ALL
Unit: sec
immediately. If it is set to 0, disable the function.
Panel / Software
ALL
Unit: N/A
ASDA-Soft
RS-232 Communication format
0: RS-232/RS485 via Modbus communication
1: RS-232 upon ASDA-Soft software
Communication
Communication
Communication
ASDA-B2
Address: 0306H
0307H
Related Section:
8.2
Address: 0308H
0309H
Related Section:
8.2
Address: 030AH
030BH
Related Section:
8.2