Chapter 7 Parameters
P2-23
NCF1 Resonance Suppression (Notch Filter) (1)
Operation
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Format: Decimal
Settings: The first setting value of resonance frequency. If P2-24 is set to 0,
P2-24
DPH1
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32 (0: Disabled)
Data Size: 16-bit
Format: Decimal
Settings: The first resonance suppression (notch filter) attenuation rate.
P2-25
NLP
Operation
Interface:
Default: 0.2 (1kW and below
Control
Mode:
Range: 0.0 ~ 100.0
Data Size: 16-bit
Format: One-digit
Example: 1.5 = 1.5 msec
Settings: Set the low-pass filter of resonance suppression. When the value
7-60
Panel/Software
ALL
Unit: Hz
this function is disabled. P2-43 and P2-44 are the second Notch
filter.
Resonance Suppression (Notch filter)
Attenuation Rate (1)
Panel/Software
ALL
Unit: dB
When this parameter is set to 0, the function of Notch filter is
disabled.
Low-pass Filter of Resonance
Suppression
Panel/Software
models) or 0.5 (other
models)
ALL
Unit: 1ms
is set to 0, the function of low-pass filter is disabled.
Communication
Communication
Communication
2 (1kW and below
models) or 5 (other
models)
0.1ms
0 ~ 1000
Decimal
15 = 1.5 msec
ASDA-B2
Address: 022EH
022FH
Related Section:
6.2.5
Address: 0230H
0231H
Related Section:
6.3.7
Address: 0232H
0233H
Related Section:
6.3.7
Revision May, 2018