Chapter 7 Parameters
P2-44
DPH2
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Format: Decimal
Settings: The second resonance suppression (notch filter) attenuation rate.
P2-45
NCF3 Resonance Suppression (Notch Filter) (3)
Operation
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Format: Decimal
Settings: The third group of mechanism resonance frequency setting value.
P2-46
DPH3
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings: The third group of resonance suppression (Notch filter)
7-68
Resonance Suppression (Notch Filter)
Attenuation Rate (2)
Panel/Software
ALL
Unit: dB
When this parameter is set to 0, the function of Notch filter is
disabled.
Panel/Software
ALL
Unit: Hz
If P2-46 is set to 0, this function will be disabled. P2-23 and P2-24
are the first group of resonance suppression (Notch filter).
Resonance Suppression (Notch Filter)
Attenuation Rate (3)
Panel/Software
ALL
Unit: dB
Decimal
attenuation rate. Set the value to 0 to disable the function of Notch
filter.
Communication
Communication
Communication
ASDA-B2
Address: 0258H
0259H
Related Section:
6.3.7
Address: 025AH
025BH
Related Section:
6.3.7
Address: 025CH
025DH
Related Section:
6.3.7