P4-10■
CEN
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 6
Data Size: 16-bit
Format: Decimal
Settings: 0: Reserved
NOTE
P4-11
SOF1 Analog Speed Input Offset Adjustment 1
Operation
Interface:
Default: Factory setting
Control
Mode:
Range: 0 ~ 32767
Data Size: 16-bit
Format: Decimal
Settings: Manually adjust the hardware offset. The adjustment function
7-90
Adjustment Function
Panel / Software
ALL
Unit: N/A
1: Execute the adjustment of analog speed input offset
2: Execute the adjustment of analog torque input offset
3: Execute the adjustment of current detector (V phase) hardware
offset
4: Execute the adjustment of current detector (W phase) hardware
offset
5: Execute the adjustment of 1 ~ 4 hardward offset
6: Execute the adjustment of IGBT ADC
The adjustment function needs to be enabled by the setting of
parameter P2-08. When adjusting, the external wiring which
connects to analog speed or torque needs to be removed
completely and must be in Servo Off status.
Panel / Software
ALL
Unit: N/A
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
Communication
Communication
ASDA-B2
Address: 0414H
0415H
Related Section: N/A
Address: 0416H
0417H
Related Section: N/A
Revision May, 2018