Delta ASDA-B2 Series User Manual page 216

Standard ac servo drive for general purpose applications
Table of Contents

Advertisement

ASDA-B2
P2-10
DI1
Operation
Interface:
Default: 101
Control
Mode:
Range: 0 ~ 0x015F
Data Size: 16-bit
Format: Hexadecimal
Settings:
P2-11
DI2
Operation
Interface:
Default: 104
Control
Mode:
Range: 0 ~ 0x015F
Data Size: 16-bit
Format: Hexadecimal
Settings: Please refer to the description of P2-10
Revision May, 2018
DI1 Funcitonal Planning
Panel/Software
ALL
Unit: N/A
(The last two codes are DI code)
 Input funciton selection: Please refer to table 7.1
 Input contact: a or b contact
0: Set the input contact as normally closed (b contact)
1: Set the input contact as normally opened (a contact)
(P2-10 ~ P2-17 and P2-36) The setting value of function
programmed
When parameters are modified, please re-start the servo drive
to ensure it can work normally.
Note: Parameter P3-06 is used to set how digital inputs (DI)
accepts commands, through external terminal or the
communication which determined by P4-07.
DI2 Funcitonal Planning
Panel/Software
ALL
Unit: N/A
(The last two codes are DI code)
Communication
Input function selection
Input contact
Not in use
Communication
Chapter 7 Parameters
Address: 0214H
0215H
Related Section:
Table 7.1
Address: 0216H
0217H
Related Section:
Table 7.1
7-55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents