Chapter 7 Parameters
P1-34
TACC Acceleration Constant of S-Curve
Operation
Interface:
Default: 200
Control
Mode:
Range: 1 ~ 20000
Data Size: 16-bit
Format: Decimal
Settings: The time that speed command accelerates from 0 to 3000 r/min.
NOTE
.
P1-35
TDEC Deceleration Constant of S-Curve
Operation
Interface:
Default: 200
Control
Mode:
Range: 1 ~ 20000
Data Size: 16-bit
Format: Decimal
Settings: The time that speed command decelerates from 3000 r/min to 0.
NOTE
7-36
Panel/Software
S
Unit: ms
P1-34, P1-35, and P1-36, the acceleration time of speed
command from zero to the rated speed, all can be set individually.
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
Panel/Software
S
Unit: ms
P1-34, P1-35, and P1-36, the deceleration time of speed
command from the rated speed to zero, all can be set individually.
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
Communication
Communication
ASDA-B2
Address: 0144H
0145H
Related Section:
6.3.3
Address: 0146H
0147H
Related Section:
6.3.3