System Configuration

1-2-1 CS1W-NC413 System Configuration Example

CS1W-NC413
Position Control Unit
Backplane
Dedicated
terminal block
(see note)
External input signals
CCW limit
CW limit
Origin
Origin proximity
Emergency stop
External interrupt
Pulse output
Stepping
Motor
Drives
Stepping Motors
4
CS1G/CS1H
CPU Unit
Connection to peripheral port
Dedicated
terminal block
24-VDC power
supply for I/F
Servo Motor Drives
or
Servo motors
Note A dedicated cable is available for connecting the PCU to the dedicated terminal
block.
Use for
setting data and
monitoring.
Power Supply Unit
Connection to
RS-232C port
External input signals
CCW limit
CW limit
Origin
Origin proximity
Emergency stop
External interrupt
24-VDC power
supply for I/F
Pulse output
Stepping
Servo Motor Drives
Motor
Drives
or
Stepping Motors
Section
Editing parameters and data.
Monitoring status.
File management.
Computer:
CX-Position (available soon)
CX-Programmer
Servo Motors