Omron CS1W-NC113 Manual page 280

Hide thumbs Also See for CS1W-NC113:
Table of Contents

Advertisement

Transferring and Saving Data
Data Memory Settings
READ DATA
CS1W-NC213
WRITE DATA and SAVE DATA
CS1W-NC113
Designation of the Operating Data Area
Data Settings
READ DATA
WRITE DATA and SAVE
DATA
Program
READ DATA
270
DM
Setting
D20000
000D
D20001
01F4
D20002
0000
The parameters for each axis are read from the flash memory of the PCU. Trans-
fer them in advance to the PCU and then save them.
DM
Setting
D20200
000D
D20201
0258
D20202
0000
The operating data area is set during programming and therefore no setting is
necessary beforehand.
• Axis Parameters
• Positioning Sequences
• Speeds
• Positions
• Acceleration and Deceleration Times
• Dwell Times
• Zones
Transfer the data needed for the operation beforehand to the PCU for both the X
and Y axes, and save it in the flash memory.
The data in D03000 through D03799 is transferred to the PCU, so set all the data
such as the axis parameters, positioning sequences, speeds and so on, in this
DM Area.
W030 and W031 are used as work words.
Contents of setting
Sets the operating data area to D00500 onwards.
p
g
Parameters read from PCU's internal flash memory.
Contents of setting
Set the operating data area to D00600 onwards.
p
g
Parameters read from PCU's internal flash memory.