Connection Examples for Different Types of Motor Drives
42
Parameter Setting Example
Word
m+4
00
01 to 03
04
05
06
07
08 to 15
m+5
00 to 03
04 to 07
08 to 11
12 to 15
Note "m" is the beginning DM word allocated when the unit number is set.
Origin Search Operation
The origin search operation is completed with the rising edge of the origin input
signal after the rising edge of the origin proximity input signal.
ORIGIN
SEARCH
Origin proximity
input signal
Origin input
signal
Pulse output
Busy Flag
15
0
0
6
m+4
0
1
0
m+5
Bits
Setting
0
CW/CCW output
0
---
0
Limit input: N.C. contact
1
Origin proximity input signal: N.O.
contact
1
Origin input signal: N.O. contact
0
Pulse output stopped with
emergency stop input signal.
0
---
0
Mode 0
0
Reverse mode 1
1
Takes origin input signal after origin
proximity input signal is received.
0
Search direction: CW
Section
0
0
0
Contents
Time
3-5