Omron CS1W-NC113 Manual page 248

Hide thumbs Also See for CS1W-NC113:
Table of Contents

Advertisement

Memory Operation
Data Settings
Axis Parameters
Positioning Sequences
Speeds
238
The values for D20004 onwards are transferred when the power is turned ON (or
at restart).
Address
Setting
1000
1011
1001
0000
1002
0301
1003
1012
1004
0000
1005
0301
1006
1012
1007
0000
1008
0302
1009
1013
100A
0000
100B
0300
Note Addresses other than the above should be set to their default settings (0).
Address
Setting
112C
00C8
112D
0000
112E
012C
112F
0000
1130
01F4
1131
0000
1132
0000
1133
0000
Note Addresses other than the above should be set to their default settings (0).
Contents of setting
Sequence #0 X axis designation
Output code: 0
Position designation: relative
Position designation: relative
Completion code: automatic
Dwell time #0
Acceleration time #0
Acceleration time #0
Deceleration time #0
Initial speed #3
Target speed #1
Sequence #1 X axis designation
Output code: 0
Position designation: relative
Position designation: relative
Completion code: continuous
Dwell time #0
Acceleration time #0
Acceleration time #0
Deceleration time #0
Initial speed #3
Target speed #1
Sequence #2 X axis designation
Output code: 0
Position designation: relative
Position designation: relative
Completion code: continuous
Dwell time #0
Acceleration time #0
Acceleration time #0
Deceleration time #0
Initial speed #3
Target speed #2
Sequence #3 X axis designation
Output code: 0
Position designation: relative
Position designation: relative
Completion code: bank end
Dwell time #0
Acceleration time #0
Acceleration time #0
Deceleration time #0
Initial speed #3
Target speed #0
Contents of setting
Speed #0
p
200 pps (C8 Hex)
pp (
Speed #1
p
300 pps (12C Hex)
pp (
Speed #2
p
500 pps (1F4 Hex)
pp (
Speed #3
p
0 pps (0 Hex)
pp (
)
Section
10-2
)
)
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-nc213Cs1w-nc433Cs1w-nc233Cs1w-nc413Cs1w-nc133