Omron CS1W-NC113 Manual page 44

Hide thumbs Also See for CS1W-NC113:
Table of Contents

Advertisement

External I/O Circuitry
Caution
!
Caution
!
Inputs
!
Caution
Connect a load of 20 mA max. to the output section. If a current greater than this
is used, it will cause damage to the PCU's internal components.
Be sure to wire the 5-VDC pulse output power supply with the correct polarity.
Wiring with the polarity reversed will result in damage to internal elements.
680 Ω
4.7 kΩ (1/2W)
680 Ω
4.7 kΩ (1/2W)
680 Ω
4.7 kΩ (1/2W)
680 Ω
4.7 kΩ (1/2W)
680 Ω
4.7 kΩ (1/2W)
680 Ω
4.7 kΩ (1/2W)
4.7 kΩ (1/2W)
150 Ω
680 Ω
For details on connecting origin input signals, refer to 38.
Use either the 24-VDC origin input signal or the 5-VDC origin input signal, but not
both. If both are connected it will damage the internal circuitry.
Do not connect the 5-VDC origin input signal input to any output circuit except
the line driver.
Output power supply, 24 VDC
Positioning completed input signal
Input common
External interrupt input (N.O. contact)
Emergency stop (N.C. contact)
(see note)
Origin proximity input
(N.O./N.C. contact) (see
note)
CW limit input (N.O./N.C.
contact) (see note)
CCW limit input (N.O./N.C.
contact) (see note)
Origin input signal (24 V)
(N.O./N.C. contact) (see note)
Origin input signal
(N.O./N.C. contact) (see
note)
Origin common
Section
3-3
Line driver output
31