Error Code Lists

Operating Memory Area
Name
Model
Error Flag
NC4j3
NC2j3
NC1j3
Error Code
NC4j3
NC2j3
NC1j3
11-5 Error Code Lists

11-5-1 Data Check at Startup

Group
Name
Data
Parameters
destruction
destruction
Data destruction
F-ROM check
data destruction
Common
Operating data
parameters
area designation
error
Operating data
area address
designation error
Parameter
designation error
288
Operating memory area
X
Y
Z
U
axis
axis
axis
axis
n+8
n+11
n+14 n+17 12
n+4
n+7
n+2
n+10
n+13
n+16 n+19 00 to
n+6
n+9
n+4
The following table shows the errors checked when power is turned ON.
Code
0001
When using the axis parameters
saved in the PCU, the
parameters saved in flash
memory are lost. It is possible
that, while saving to flash
memory, the PCU's power supply
was interrupted, there was noise,
or there was an error in flash
memory.
0002
The following data saved in flash
memory will be lost:
Zones, positioning sequences,
speeds, acceleration/deceleration
data, positions, and dwell times.
It is possible that, while saving to
flash memory, the PCU's power
supply was interrupted, there was
noise, or there was an error in
flash memory.
0003
The flash memory error data
saved in flash memory is lost
(OMRON maintenance data is
lost). It is possible that, while
saving to flash memory, the
PCU's power supply was
interrupted, there was noise, or
there was an error in flash
memory.
0010
The operating data area
designation (m) is incorrect.
• Area designation: Set to a setting
other than 00, 0D, or 0E.
• Bank designation: Set to a set-
ting not in the range 00 to 0C,
when 0E is set for the area desig-
nation.
0011
The designation of the beginning
word of the operating data area's
address (m+1) is outside the
settable range.
0013
The axis parameter designation
(m+2) is not set to 00 or 01.
Bit
1: Error occurred
0: No error
Error code
15
(A code of 0000 indicates normal operation.)
Cause
In this condition, only the data
transfer (read and write) and data
save operations can be performed.
The PCU's axis parameters and data
are all returned to their default
values. After transferring the
parameters again for all axes, save
the parameters and either reset the
power supply or restart the Unit. If
po e s pp y o es a
the error persists, it is possible that
there is a fault in flash memory, and
so it may be necessary to replace the
PCU.
When this error occurs, operation
can be continued by performing error
reset. Execute the next operation
after performing error reset.
In this condition, only the data save
operations can be performed. All of
the axes' parameters and all data will
be returned to their default values.
After correcting the common
parameters (refer to Section 4), reset
the power supply or restart the PCU.
Section
11-5
Contents
Remedy
e U