Linear Interpolation

INCH command
switch
W03000
10-4 Linear Interpolation

10-4-1 Two-axis Linear Interpolation

Overview
D00000 and D00001:
D00002 and D00003:
200213
Inching
Busy Flag
direction
switch
Inching
direction
switch
• Used for carrying out positioning on multiple active axes.
• The only interpolation method available is linear interpolation.
• The positioning sequence for the active axis designates the axes to be used in
interpolation.
Inching pulses in CW direction (set positive value)
Inching pulses in CCW direction (set negative value)
Takes the rising
DIFU
W03000
edge of the INCH
command switch.
Transfers the number
MOVL
of pulses in the CCW
D00002
direction.
D00508
Transfers the number
MOVL
of pulses in the CW
D00000
direction.
D00508
Speed: 100 pps (64 Hex)
MOVL
#00000064
D00510
Acceleration time: 0 ms
MOVL
#00000000
D00512
Deceleration time: 0 ms
MOVL
#00000000
D00514
RELATIVE MOVEMENT command
200004
END