Origin Search Operation
Origin detection method
2: Origin proximity input signal not
used
3: Limit input signal used instead of
origin proximity input signal
Origin detection method
0: Takes origin signal after origin
proximity signal turns ON (↑) and
OFF (↓).
142
0
Origin input signal
Pulse output
Note If the direction of operation is reversed, the reverse will be sudden, without
deceleration or acceleration.
An origin detection method error (error code 1607) is generated and settings are
not possible.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Note A limit signal is input and operation is stopped without deceleration.
Origin search operation
0: Reversal mode 1
Origin search proximity speed
Start
Stop
CW limit (See note.)
Stop
Start
Stop
Start
Origin search operation
1: Reversal mode 2
Stop
Stop
Start
Section
6-4
CW limit (See note.)
Start Limit Stop
(Error code 6200)