Origin Search Operation
Origin
proximity
input signal
Origin
adjustment
command
output
Positioning
completed
input signal
Pulse
output
Busy Flag
When the origin adjustment command (H-RET) is received by the Servo motor
Drive, the internal error counter is reset by the Z-phase of the encoder and posi-
tioning stops.
Servo Motor Drive processing (with signal level ON condition set at 1)
Origin adjustment
command output
Z-phase signal
Positioning
completed
The stop position is the same in Mode 1 and Mode 2. For an operation where the
start location of the origin search is different or where the deceleration time is
short, refer to the previously-described Mode 1. In Mode 3, if deceleration is not
completed when the origin proximity input signal is turned ON and then turned
OFF, an origin adjustment signal will be output after deceleration is completed.
Origin Detection Method: 1
Deceleration starts on the rising edge of the origin proximity input signal, and an
origin adjustment command is output when deceleration is completed.
Start
Stops here
Time
Stop
Section
6-4