System Configuration - Omron SYSMAC C500-NC113 Operation Manual

Position control units
Table of Contents

Advertisement

1-2

System Configuration

Stepping Motor Driver
Connection
NC Support Tool
Pulse
outputs
The Position Control Unit receives control signals (CW limit, CCW limit, origin,
origin proximity, emergency stop, interrupt) from devices and/or a control panel,
and outputs pulse signals to a stepping motor driver.
Pulse
outputs
Power
supply
Stepping
motor driver
Stepping motor
CCW limit
switch
Origin proximity
switch
C500-NC113/211
Position Control Unit
Input
Power
supply
Emer-
gency
stop
switch
Stepping
motor driver
Stepping motor
CW limit
switch
Origin signal
switch
Section
Control panel
Interrupt
input
switch
Note The NC113 is a one-axis
control Unit.
1-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac c500-nc211

Table of Contents