Omron CS1W-NC113 Manual page 94

Hide thumbs Also See for CS1W-NC113:
Table of Contents

Advertisement

Axis Parameter Area
Software Limits
Word Address and
Enable Timing
Bit Configuration
Settings
Explanation
Initial Pulse Designation
Word Address and
Enable Timing
within this time, a positioning timer timeout error (error code 8600) will be gener-
ated. The positioning monitor time is set in the range 0 to 9,999 ms as 16-bit
unsigned data.
If the positioning monitor time is set to 0, operation will proceed in one of the fol-
lowing ways, depending on the kind of operation being performed.
• Origin search operation: Waits until positioning completed signal turns ON.
• Other operation (jogging, direct operation, etc.): Positioning completed signal
ignored.
The word addresses and enable timing for the software limit settings are shown
below.
Word
(PCU internal address)
NC1j3
NC2j3
X axis
Y axis
Z axis
m+25
m+53
m+81
(0019)
(0035)
(0051)
m+26
m+54
m+82
(001A)
(0036)
(0052)
m+27
m+55
m+83
(001B)
(0037)
(0053)
m+28
m+56
m+84
(001C)
(0038)
(0054)
The bit configurations for the word addresses in the above table are shown
below.
15
CCW software limit (leftmost word) (Hex)
15
CW software limit (leftmost word) (Hex)
The software limits can be set to any values in the following range:
C0000001 to 3FFFFFFF Hex (±1,073,741,823 pulses)
The default settings are C0000001 (--1,073,741,823) for the CCW software limit
and 3FFFFFFF (1,073,741,823) for the CW software limit.
These settings specify the CCW and CW software limits (in pulse units). The
respective software limits are set in the range --1,073,741,823 to 1,073,741,823
pulses using two words (the leftmost word and the rightmost word) as 32-bit
unsigned data. If the CW software limit is set to less than or equal to the CCW
software limit, the software limit function be disabled and the present position will
taken to be 0 when operation starts. For details on software limit operation, refer
to 9-9 Software Limit.
The word addresses and enable timing for the initial pulse designation are
shown below.
Name
NC4j3
U axis
m+109
CCW software limit
(006D)
(rightmost word)
m+110
CCW software limit
(006E)
(leftmost word)
m+111
CW software limit
(006F)
(rightmost word)
m+112
CW software limit
(0070)
(leftmost word)
00 15
CCW software limit (rightmost word) (Hex)
00 15
CW software limit (rightmost word) (Hex)
Section
4-3
Enable timing
With operating
command
With operating
command
With operating
command
With operating
command
00
00
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-nc213Cs1w-nc433Cs1w-nc233Cs1w-nc413Cs1w-nc133

Table of Contents