CHAPTER 1 MMB Web-UI (Web User Interface) Operations
Navigation bar
1st level
1.1.6

Web-UI menus in maintenance mode

Some windows have operating restrictions when maintenance mode is set. These restrictions apply to the user who
sets maintenance mode (referred to below as maintenance personnel) and other users (referred to below as non-
maintenance personnel).
The following table lists the Web-UI window restrictions that apply to maintenance personnel and non-maintenance
personnel in maintenance mode.
The five types of maintenance mode are as follows.

TABLE 1.7 Types of maintenance mode

Maintenance mode
Hot System Maintenance
(Target unit not included in a partition)
Active (system) for work
Hot Partition Maintenance
(Target unit in a running partition)
Active (partition) for work
Warm System Maintenance
(Target unit in a powered off partition)
Partition stopped for work
Cold System Maintenance
(All partitions powered off, breaker on)
Stopped (standby) for work
Cold System Maintenance
(All partitions powered off, breaker off)
Stopped (AC off) for work
The following sections outline the Web-UI menus that are available in maintenance mode for each type of user
privilege.
-
1.1.7 Web-UI menus in maintenance mode (Administrator)
-
1.1.8 Web-UI menus in maintenance mode (Operator)
-
1.1.9 Web-UI menus in maintenance mode (Partition Operator)
-
1.1.10 Web-UI menus in maintenance mode (User)
-
1.1.11 Web-UI menus in maintenance mode (CE)
-
1.1.12 Web-UI menus in maintenance mode (maintenance personnel)
2nd level
3rd level
Detailed Setup
For maintenance work on the target unit not included in
a partition. The work can be performed without stopping
jobs.
For maintenance work on a partition that is still operating
while under maintenance. This work can be performed
without stopping jobs.
For maintenance work on the partition under maintenance
or the partition containing the target maintenance unit.
The partition must be stopped during maintenance.
The partitions not under maintenance need not be stopped.
For maintenance work that requires the system to be
stopped. All jobs are stopped.
For maintenance work that requires the system to be
stopped and the AC power to be turned off (MMB power
off). All jobs are stopped.
34
Privileges
Remarks
RW
Description
C122-E110-10EN