Fujitsu PRIMEQUEST 1000 Series Tool Reference page 263

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Tool Reference
CHAPTER 2 MMB CLI (Command Line Interface) Operations
Users with Partition Operator privileges can perform this operation only on partitions under their management.
If the specified parameters include a partition not under management, an error message appears. The specified
partition cannot be operated.
Privileges: Administrator, Operator, Partition Operator (only for a partition under
management)
(1) Syntax
power off {partition} [ all | <partition#> [, | -] <partition#>]
{force}
(2) Options
Partition: This option shuts down the operating system on the partition identified by the specified partition number.
Then, it powers off the partition. This parameter can be omitted.
However, even if the parameter is omitted, processing assumes that the partition parameter is specified. Therefore,
a partition must be specified.
Partitions are specified as follows:
- Specify "all" (for all defined partitions).
- Specify partition numbers delimited by commas.
- Specify a range of partition numbers.
force: This option forcibly powers off the partition without shutting down the operating system.
(3) Usage example
None
(4) Messages
The following messages appear for this CLI command.
For details on the messages, see the PRIMEQUEST 1000 Series Message Reference (C122-E111EN).
The specified parameter is invalid.
The specified partition number is invalid.
Unable to execute this command because the system is under maintenance.
Unable to execute this command because the Partition#x is under maintenance.
Unable to power off the partition#%d.
Unable to force power off on the partition#%d.
Command Failed. Code=0x%04X, 0x%02X
Unable to power off the Partition#n because you have not authority to operate this partition.
Unable to execute this command on a standby MMB.
Unable to power off the partition(s) because the partition which does not have authority to you is included
in the specified parameter.
231