PRIMEQUEST 1000 Series Tool Reference
CHAPTER 1 MMB Web-UI (Web User Interface) Operations
FIGURE 1.15 [Fans] window
Once a detected error is shown for the status of a fan, the display retains the error condition until the fan is replaced
or the [Status Clear] button is clicked to clear the status.
Remarks
If a fan speed error persists after the [Status Clear] button is clicked, the status changes to [Failed]. Therefore, if
the fan speed is abnormal, clearing the fan status may not change the status from [Failed].
TABLE 1.39 Display items in the [Fans] window
Item
Fan Speed Mode
Displays the fan speed mode.
Fan Redundancy
Displays the fan redundancy status.
Status
Displays the status of each fan.
- FULL
- High (The mode changes to the high-speed mode when a temperature abnormality
or redundancy is no longer detected.)
- Normal
- Low
- Optimal FAN Control Cooling
- Redundant: The fans are redundant.
- Non-redundant: Sufficient Resource: The fan has sufficient resources to maintain
system operation even though fan redundancy has been lost.
- Non-redundant: Insufficient Resource: Fan redundancy has been lost and the fan
has insufficient resources to maintain system operation.
- OK
Description