CHAPTER 1 MMB Web-UI (Web User Interface) Operations
Item
Role
Part Number
Serial Number
MAC
USER port
address
Maintenance
port
Firmware Version
Location LED
Reset MMB
Switch Over to MMB
Enable/Disable MMB
Voltage
+5VL
+3.3VL
+2.5VL
+1.8VL
- OK
- Not-present
- Warning
- Degraded
- Failed
Displays the MMB operation status.
- Active
- Standby
- Disabled
Displays the part number of the MMB.
Displays the serial number of the MMB.
Displays the MAC address of the MMB management port.
00:00:00:00:00:00
Displays the MAC address of the MMB port.
00:00:00:00:00:00
Displays the version of the MMB firmware.
Displays the display state of the Location LED.
The 3 display states are as follows:
- On: The LED is on.
- Off: The LED is off.
- Blink: The LED is blinking.
You can also control the On, Off, and Blink states of the Location LED by clicking
the [On], [Off], and [Blink] buttons, respectively.
Resets the MMB if this check box is checked.
If the check box is checked, you cannot set the [Switch Over to MMB] described
below.
Switches the Active/Standby of the MMB if this check box is checked.
If the check box is checked, you cannot set the [Reset MMB] described above.
Remarks
Unless two MMBs are mounted, this window does not display this check box.
Controls Enable/Disable setting of the MMB.
The status of any MMB that is subsequently added to the PRIMEQUEST 1000 series
server is Disable. The other MMB, which is running, is already in the Active status.
To set this added MMB to the Standby status, it must be set to Enable here.
Displays the current voltage or threshold.
- Warning (Low/High)
- Critical (Low/High)
If no threshold is set, this field displays "-".