CHAPTER 4 PSA CLI (Command Line Interface) Operations
The following example shows execution of the command for copying the filter definition file used for
update from the /tmp/filter directory. The filter definition was extracted into that directory. Stop PSA,
and execute the fltcpy command from /tmp/filter. After the command is completed, restart PSA.
# /sbin/service y30FJSVpsa stop
# /opt/FJSVpsa/sh/fltcpy -d /tmp/filter
# /sbin/service y30FJSVpsa start (*)
* After fltcpy command execution, PSA starts automatically at operating system restart. Therefore,
this operation is not necessary.
- Forced update procedure
The following example shows the restoring of an old version of a filter definition (located in /tmp/
filter).
# /sbin/service y30FJSVpsa stop
# /opt/FJSVpsa/sh/fltcpy -f -d
# /opt/FJSVpsa/sh/fltupdate -f
# /sbin/service y30FJSVpsa start
- In Windows
- Typical update procedure
The following example shows execution of the fltcpy command from the C:\temp\filter directory. The
filter definition used for update was extracted into that directory. Stop PSA, and execute the fltcpy
command from C:\temp\filter. After the command is completed, restart PSA.
> net stop "PRIMEQUEST Server Agent"
> fltcpy
> net start "PRIMEQUEST Server Agent" (*)
* After fltcpy command execution, PSA starts automatically at operating system restart. Therefore,
this operation is not necessary.
- Forced update procedure
The following example shows the restoring of an old version of the filter definition (C:\temp\filter).
> net stop "PRIMEQUEST Server Agent"
> fltcpy
> fltupdate -f
> net start "PRIMEQUEST Server Agent"
(4) Output messages
The following messages appear for this CLI command.
For details on the messages, see the PRIMEQUEST 1000 Series Message Reference (C122-E111EN).
FJSVpsa: E 02700 fltupdate initialization failed