PRIMEQUEST 1000 Series Tool Reference
CHAPTER 1 MMB Web-UI (Web User Interface) Operations
You can specify clearing of the error status for any component by clicking the [Status Clear] button in the [SB#x]
window.
After an error is detected in a component of the SB, you can clear the error status to use the component again from
the next reboot. If the same error is detected during the reboot, the error status of the component is recorded again.

FIGURE 1.20 [SB#x Status Clear] window (Message display)

(1) Menu operations
[System] - [SB] - [SB#x] - [Status Clear] button
(2) Window operations
1. Specify the component you want to clear as follows.
- To clear all the components, check [Clear All Status].
- To clear the error status of one component, check [Clear Specified Status], and then check the [Status
Clear] check box of that component.
- To clear the status of common parts, check the [Clear Status of common parts] check box.
2. Click the [Apply] button.
This clears the status of the specified components.
Displayed contents when no CPUs or DIMMs are mounted
An SB with no CPUs or DIMMs mounted is degraded from partitions.
In this case, [SB Status] displays [Failed] so that the user can be aware of CPUs or DIMMs being unmounted. Also,
the following descriptions will appear above the CPU or DIMM configuration table to make this error easier to
notice.
"*It is necessary to install at least one CPU in SB#x." (for CPUs)
"*It is necessary to install at least one DIMM set in SB#x." (for DIMMs)