Fujitsu PRIMEQUEST 1000 Series Tool Reference page 301

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Tool Reference
CHAPTER 2 MMB CLI (Command Line Interface) Operations
partition home | partition name |
partition mirror_mode | partition pci_express_mode |
ssh | ssh_port | telnet | telnet_port | ip | hostname | maintenance_ip |
sysconf power_feed_mode | sysconf power_restoration_policy |
sysconf power_on_delay | sysconf altitude | sysconf psu_redundant_mode |
mmbcontrol reset | mmbcontrol switch_over | reserved_sb |
snmp sys_location | snmp sys_contact | snmp community |
snmp trap | snmp test_trap ]
set date MMDDhhmm{{CC}YY}{,ss}
set timezone <timezone>
set gateway <ip address>
set gateway_ipv6 {auto} <ip address>
set [ http | https | ssh | telnet ] [ enable | disable ]
set [ http_port | https_port | ssh_port | telnet_port ] <port>
set partition home <partition#> SB <SB#>
set partition name <partition#> <partition name>
set partition mirror_mode <partition#> [disable | enable] {quiet}
set partition pci_express_mode <partition#> [ flexible | fixed ] {quiet}
set ip <ip address> <netmask>
set ipv6 {auto} <ip address/prefix>
set hostname <hostname>.<domain name>
set maintenance_ip <ip address> <netmask> <gateway address> <smtp address>
set sysconf power_feed_mode [single | dual] {quiet}
set sysconf power_restoration_policy [on | off | restore | sync] {quiet}
set sysconf power_on_delay <time> {quiet}
set sysconf altitude <altitude>
set sysconf psu_redundant_mode [redundant | non_redundant] {quiet}
set mmbcontrol reset [0 | 1] {quiet}
set mmbcontrol switch_over {quiet}
set reserved_sb <SB#> <partition#> {quiet}
set snmp sys_location <location> {quiet}
set snmp sys_contact <contact> {quiet}
set snmp community <community> <ip or mask> [1 | 2] [ro | rw] {quiet}
set snmp trap <community> <ip> [1 | 2] {quiet}
set snmp test_trap {quiet}
show [ access_control | active_mmb | date | timezone | gateway |
http | http_port | https | https_port |
partition configuration | partition home | partition name |
partition mirror_mode | partition pci_address_mode |
ssh | ssh_port | telnet | telnet_port | ip | hostname | network | maintenance_ip |
update_status | firmware_version | exit_code |
sysconf power_feed_mode | sysconf power_restoration_policy |
sysconf power_on_delay | sysconf altitude | sysconf psu_redundant_mode |
sysconf input_voltage | reserved_sb | user_list |
snmp sys_location | snmp sys_contact | snmp community | snmp trap | ipv6 | gateway_ipv6 ]
show partition configuration [ all | free | <partition#> {[, | -] <partition#>}]