CHAPTER 2 MMB CLI (Command Line Interface) Operations
Unable to power on the partition#%d due to DIMM does not satisfy requirements of Mirror Mode.
Unable to power on due to mismatch between supply voltage and input voltage.
Unable to power on the partition#%d due to abnormal DIMM composition.
Unable to power on the partition#%d due to abnormal SB composition.
Unable to power on the partition#%d due to abnormal VRM composition.
2.2.7

reset

The reset command specifies a Hard Reset of the specified partition.
If the partition specified in the parameter is not configured, the partition is ignored.
If the power to the specified partition is not on, the command has no effect on the partition.
Users with Partition Operator privileges can perform this operation only on partitions under their management.
If the specified parameters include a partition not under management, an error message appears. The specified
partition cannot be operated.
Privileges: Administrator, Operator, Partition Operator (only for a partition under
management)
(1) Syntax
reset {partition} [<partition#> [, | -] <partition#>] {quiet}
(2) Options
partition: This option specifies a Hard Reset of the partition identified by the specified partition#. This parameter
can be omitted.
However, even if the parameter is omitted, processing assumes that the partition parameter is specified. Therefore,
a partition must be specified.
Partitions are specified as follows:
- Specify partition numbers delimited by commas.
- Specify a range of partition numbers.
quiet: This option executes the command without user interaction.
(3) Usage example
Example: Specifying a reset of Partition#1 as a user with Administrator privileges
Administrator>reset partition 1
Are you sure you want to Reset to Partition#1? [Y/N]: Y
Administrator>
(4) Messages
The following messages appear for this CLI command.
For details on the messages, see the PRIMEQUEST 1000 Series Message Reference (C122-E111EN).
Are you sure you want to Reset to Partition#%d? [Y/N]:
The specified parameter is invalid.