Deleting An End-To-End Monitor Pair; San Top Talker Monitoring; Configuring A Fabric Mode Top Talker Monitor - Brocade Communications Systems Brocade 8/12c User Manual

Brocade network advisor san user manual v11.1x (53-1002167-01, may 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

27

SAN Top Talker monitoring

Deleting an end-to-end monitor pair

To delete an end-to-end monitor pair, complete the following steps.
1. Select Monitor > Performance > End-to-End Monitors.
2. Select the end-to-end monitor pair you want to delete from the Monitored Pairs table.
3. Click Delete Monitor.
4. Click OK.
SAN Top Talker monitoring
NOTE
Top Talkers requires the Advance Performance Monitoring (APM) license on the device.
NOTE
Top Talkers requires Fabric OS version 6.2 or later.
NOTE
On the 8 Gbps 8-FC port, 10 GbE 24-CEE port Switch, Top Talkers is only supported on the 8 Gbps
FC Ports.
Advanced Performance Monitoring enables you to create Top Talker monitors on selected devices.
Use Top Talkers to display the connections which are using the most bandwidth on the selected
device or port. Top Talkers can be enabled on the device or one of the F_ports on the device. You
can only use Top Talkers to view real-time performance data. Data is only collected while the Top
Talkers dialog box is open; it is not persisted in the database.
You can have multiple Top Talker monitors configured at the same time. You can monitor up to 10
switches for Fabric mode Top Talkers and 32 ports and 10 switches for F_Port Top Talkers;
however, you can only monitor one device or port for each Top Talker you configure.
NOTE
If the Fabric OS device is configured for Fibre Channel routing (FCR), you can only configure a Top
Talker monitor on the following devices:
- 16 Gbps Backbone Chassis with a FC 16 Gbps 32-port or 48-port blade
- 16 Gbps 48-port switch

Configuring a fabric mode Top Talker monitor

NOTE
A fabric mode Top Talker and an end-to-end monitor cannot be configured on the same fabric. You
must delete the end-to-end monitor before you configure the fabric mode Top Talker.
NOTE
A fabric mode Top Talker and an F_port mode Top Talker cannot be configured on the same fabric.
You must delete the F_port mode Top Talker before you configure the fabric mode Top Talker.
796
The Set End-to-End Monitor dialog box displays.
Brocade Network Advisor SAN User Manual
53-1002167-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network advisor 11.1.xBrocade bladesystem 4/24

Table of Contents