Lldp Timer Reinit-Delay; Lldp Timer Tx-Delay - 3Com 5500-EI PWR Reference Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

Parameters
value: Interval to send trap messages, in the range 5 to 3600 (in seconds).
Description
Use the lldp timer notification-interval command to set the interval to send trap messages.
Use the undo lldp timer notification-interval command to restore the default.
By default, the interval to send trap messages is 5 seconds.
Examples
# Set the interval to send trap messages to 8 seconds.
<Sysname> system-view
[Sysname] lldp timer notification-interval 8

lldp timer reinit-delay

Syntax
lldp timer reinit-delay value
undo lldp timer reinit-delay
View
System view
Parameters
value: Initialization delay period to be set, in the range 1 to 10 (in seconds).
Description
Use the lldp timer reinit-delay command to set the initialization delay period.
Use the undo lldp timer reinit-delay command to restore the default.
By default, the initialization delay period is 2 seconds.
Examples
# Set the initialization delay period to 4 seconds.
<Sysname> system-view
[Sysname] lldp timer reinit-delay 4

lldp timer tx-delay

Syntax
lldp timer tx-delay value
undo lldp timer tx-delay
View
System view
1-22

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

5500-ei series

Table of Contents