# Set the maximum number of concurrent tests to 4.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping-agent max-requests 4

jitter-interval

Syntax
jitter-interval interval
undo jitter-interval
View
remote-ping test group view
Parameters
interval: Interval in milliseconds between jitter test packets. The value is in the range of 10 to 1000.
Description
Use the jitter-interval command to configure the interval between sending jitter test packets.
Use the undo jitter-interval command to restore the default.
By default, the interval between sending jitter test packets is 20 milliseconds.
Related commands: jitter-packetnum.
The jitter-interval command applies to jitter tests only.
Examples
# Set the interval between sending jitter test packets to 30 milliseconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping administrator jitter
[Sysname-remote-ping-administrator-jitter] test-type jitter
[Sysname-remote-ping-administrator-jitter] jitter-interval 30

jitter-packetnum

Syntax
jitter-packetnum number