[Sysname] remote-ping administrator http
[Sysname-remote-ping-administrator-http] test-type http
[Sysname-remote-ping-administrator-http] http-operation post

http-string

Syntax
http-string string version
undo http-string
View
remote-ping test group view
Parameters
string: HTTP operation string used to specify the webpage to be accessed. It can consist of 1 to 230
characters.
version: HTTP version, a string of 1 to 12 characters. At present, this argument can be HTTP/1.0 or
HTTP/1.1, where HTTP must be capitalized.
Description
Use the http-string command to configure the HTTP operation string and HTTP version.
Use the undo http-string command to remove the configured HTTP operation string and version.
By default, no HTTP operation string and HTTP version are configured.
Note that the http-string command applies to HTTP tests only.
Related commands: http-operation.
Examples
# Configure the webpage to be accessed by an HTTP test as /index.htm and the HTTP version as
HTTP/1.0.
<Sysname> system-view
[Sysname] remote-ping administrator http
[Sysname-remote-ping-administrator-http] test-type http
[Sysname-remote-ping-administrator-http] http-string /index.htm HTTP/1.0

remote-ping

Syntax
remote-ping administrator-name operation-tag
undo remote-ping administrator-name operation-tag
View
System view
1-22